Building System Specifications
                                                                           Refer to below table for detail and level of achievement recommendations for each category.
                Building System  Prototype     Value             Reference                          System Description
                                Specification
              Walls            R-Value      ≥ 20         IECC 2012                3 inch rigid XPS
              Roof             R-Value      ≥ 30         IECC 2009                5.5 inches of closed-cell spray foam in truss cavity
              Floor            R-Value      ≥ 19         IECC 2012                Fiberglass-batts underneath floor, if applicable
              Windows          U-Value      ≤ 0.3        ENERGY STAR              NFRC Certified Window
                               SHGC         ≤ 0.25       ENERGY STAR              NFRC Certified Window
              Air Leakage      ACH50        ≤ 3          IECC 2012                Achieve continuous air barrier by sealing all wall, ceiling, and floor penetrations
                                                                                  to the outside
              Mechanical       Constant CFM  20          ASHRAE 62.2              Energy Recovery Ventilator (ERV); ducts deliver fresh air
              Ventilation

              Space Conditioning  SEER      ≥ 14.5       ENERGY STAR              Ductless mini-split heat pump
                               HSPF         ≥ 8.2        ENERGY STAR
              Water Heater     EF           ≥ 0.90       ENERGY STAR              Tankless; gas
              Appliances                                 ENERGY STAR              ENERGY STAR certified, if applicable
              Lighting                                   ENERGY STAR              LED; ENERGY STAR certified
              Plumbing fixtures  Gallons Per   0.5       WaterSense               Low-flow bathroom sinks
                               Minute (GPM)
                               Gallons Per   1.5         WaterSense               Low-flow kitchen sink/shower
                               Minute (GPM)
                               Gallons Per Flush   ≤ 1.28  WaterSense             Dual-flush water closets
                               (GPF)
                                          Table 1. Optimized Building Performance Implementation Requirements Table