Page 46 - 2012 SDCA Project
P. 46

Advantages:                                                                   and material cost.                                                           Disadvantages:
        • Reduced water and sewer cost                                                                                                                             • May lead to less water returned to the lake

        • Qualify for USGBC LEED point                                                Advantages:                                                                  • Underground tank may be required
        • Installation in new and retrofit situations                                 • Reduced energy usage                                                       • Energy used to pump water to final destination
        • Environmentally friendly                                                    • Qualify for USGBC LEED point
                                                                                      • Installation in new and retrofit situations                                CONTROLS SYSTEM
        Disadvantages:                                                                • Environmentally friendly
        • Educating janitorial staff on who replaces batteries                        • Easy to install by experienced installer                                   I. INTRODUCTION


        VI. SOLAR POWERED POINT-OF-USE WATER HEATER                                   Disadvantages:                                                               Building Controls are always the most misunderstood and
                                                                                      • New technology for the user - requires training                            mistreated application of those included into the Building

        Point-of-use tankless water heaters, designed for basic low-                                                                                               Systems discipline which typically includes Mechanical-
        flow point of use applications, are economical, ultra-compact  VII. RAINWATER HARVESTING COLLECTION SYSTEM                                                 HVAC, Electrical, Plumbing, & Communications. This
        and attractive. The Mini Series is best suited to applications                                                                                             industry is geared to provide an “all inclusive” stream of
        with a relatively constant flow rate. If the flow rate is likely to           Rainwater harvesting is the accumulating and storing, of                     technologies and information for which the potential Owner/
        fluctuate in your application due to varying water demands                    rainwater. Rainwater harvesting systems channel rainwater                    User tends to acquire a certain level of automated
        or changes in well pump pressures, etc., we recommend                         that falls on to a roof into storage via a system of gutters and advantages that includes a myriad of little conveniences.
        that you consider a tankless water heater with thermostatic                   pipes. The collected rainwater can be reused to irrigate                     In short the Lithonia Woman’s Club building needs a simple
        control and flow-based power modulation technology.                           vegetation. Additional uses of the collected water could be                  “smart” controls system configured to be “User Friendly” in
        Due to their small size, the Stiebel Eltron Mini Tankless                     to flush toilets. Local codes must be understood in order to                 terms of the non-technical staff that administers or run the
        Water Heaters conveniently fit directly under the sink or                     follow rainwater requirements.                                               place.
        adjacent cupboard or closet, so they deliver hot water

        to the sink almost instantly. By locating the heater right                    Advantages:                                                                  ADDITIONAL SYSTEM
        near the point-of-use, you can also eliminate thermal heat                    • Reduced water usage
        loss commonly associated with long pipe runs. In new                          • Qualify for USGBC LEED point                                               I. SUNPOWER SYSTEMS
        construction applications, you also eliminate the need to                     • Installation in new and retrofit situations
        run a hot water line all the way from the main central water                  • Environmentally friendly                                                   SunPower® Residential Solar Panels
        heater which can save you significant money in plumbing

        46 RAGS 2012