Page 47 - 2012 SDCA Project
P. 47

Solar power lowers your energy costs by channeling                            I. BUILDING                                                                  offset by the energy savings of LED as well as reduced
        the suns energy. It hedges against rising utility rates,                                                                                                   cost of maintenance. LED lamps have the longest life of

        increasing your energy savings over time, and requires little                 The existing building has a variety of lighting fixtures                     available sources. The cost to maintain and replace lamps
        maintenance. (http://us.sunpowercorp.com) 1-800-786-7693                      that use incandescent bulbs and fluorescent bulbs. We                        in the difficult-to-reach soffits make LED’s a great option
        Sun Power Systems provide a turnkey product for the                           recommend replacing all lamps and bulbs with energy                          for this application. Recommend controlling this lighting by
        Owner. The final installation incorporates a flat screen                      efficient fluorescent bulbs and T8 lamps for the fluorescents                photocell-on and timer-off.
        monitor located per the owner request. The monitor offers                     fixtures. T8 lamps have the highest luminous efficacy
        real time solar energy collection data at the facilities site.                (efficiency of light output to power used).                                  II. MOTION SENSORS
        Community center users can get a first hand look at this
        impressive energy conservation feature. Children will learn                   INTERIOR LIGHTING CONTROLS                                                   Recommend using flood lighting controlled by motion sensor
        more about energy conservation as they use the interactive                                                                                                 for security purposes.

        monitor to view other energy conservation links. Free site                    I. OCCUPANCY SENSORS
        assessment by SunPower Personnel.                                                                                                                          STRUCTURAL SYSTEMS
                                                                                      Recommend utilizing occupancy sensors for energy-savings
        Advantages:                                                                   where possible, including:                                                   1.      There exists a visible & measurable settling
        • Reduced energy usage                                                        o Switch-type passive infrared sensors in all the rooms                      underneath floor beam carrying the eastern wall of the Main
        • Qualify for USGBC LEED point                                                except the Assembly Room.)                                                   Hall. Jacking up is not recommended as it might lead to
        • Installation in new and retrofit situations                                 o Ceiling-mounted ultrasonic type in bathrooms.                              potential cracking in drywall etc. Instead, we recommend
        • Environmentally friendly                                                    o Ceiling-mounted passive infrared elsewhere in the multi-                   stiffening the existing beam in place with added vertical
        • Interactive monitor for community to learn more about solar  purpose rooms,                                                                              support in the crawl space.
        power                                                                         kitchen, and hallways.
                                                                                                                                                                   2.      Inspection of roof structure in the attic reveals that

        Disadvantages:                                                                EXTERIOR LIGHTING                                                            there are at least two buckled vertical roof supports due to
        • May not produce substantial amount of energy                                                                                                             excess roof loads. It is advised that further inspection of roof
        • Space required on roof for solar panels                                     I. EXTERIOR Lighting , PHOTOCELL AND TIMERS                                  loads be done and potentially adding extra support in those
                                                                                                                                                                   areas where vertical buckling is clearly visible.
        LIGHTING RECOMMENDATIONS                                                      Recommend using LED lighting. There is a higher up-front
        INTERIOR LIGHTING                                                             cost for LED over other sources; however this cost will be
   42   43   44   45   46   47   48   49   50   51   52