BUILDING ENVELOPE












                                                                                                                                For energy, it is always best to start with the building’s envelope (the


                                                                                                                                skin, openings and roof of a building’s exterior). The more efficient the

                                                                                                                                envelope, the less energy will be required for conditioning of the interior


                                                                                                                                spaces and the spaces will be much more comfortable to occupy.





                                                                                                                                Another goal of this approach is to make the ongoing utility costs as low

                                                                                                                                as possible (and thus concentrate more of the budget on services), as


                                                                                                                                well as to make the buildings more comfortable and easy to maintain.

                                                                                                                                Although the existing windows are insulating glass in aluminum frames,


                                                                                                                                they are old and not in great condition and are not as energy efficient


                                                                                                                                as current ones. The windows and exterior doors should all be replaced

                                                                                                                                with new, energy efficient glazing systems. A thermally broken,


                                                                                                                                aluminum clad wood type system with insulating glass and low-e


          New aluminum                                  Existing windows                                                        coatings would be appropriate for this building. They could be operable,
          clad wood window                              showing                                                                 with measures to limit child accessibility, or not.

          section                                       condensation


                                                                                              Insulated
                                                                                                                                The exterior brick seems to be in pretty good condition, but there were
                                                                                              glazing with a
                                                                                              low-E coating                     a few areas where penetrations for HVAC piping were not properly

                                                                                              helps minimize                    sealed and some deterioration of the brick joints has occurred. It is
                                                                                              heat transfer

                                                                                              and solar gain                    recommended to patch and seal any deteriorated joints and openings.