Page 45 - 2014 SDCA Project
P. 45
I want details! How will the JADC get it done?
STRUCTURAL SITE PLANNING ELECTRICAL MECHANICAL
Super-insulated building Full on-site storm water High efficiency electronics and Active air quality monitoring
envelope with R-47 walls, R- infiltration, pervious grass appliances, 50 KW Solar with MERV 12 filtration, ultra-
60 high SRI cool roof, paver parking lot, rainwater Photovoltaic array with DC-direct high efficiency energy recovery
thermal bridge-free irrigated landscape tie to 100 KWH of battery ventilators, solar condensing
detailing, air-tight envelope architecture, edible storage, 380 Volt DC micro grid dehumidification, dedicated
with open diffusion and rain perennial plants and backbone for DC-powered 24 Volt micro-ERVs for bathrooms and
screens, advanced windows abundant outdoor LED lighting, PCs, ECM kitchens, ultra-high SEER heat
and doors, active and gathering spaces. mechanicals and ceiling fans, a pumps in micro-zones, low
passive control of year- Single mode optical fiber energy ceiling fans, elevated
round solar heat gains. backbone enabling centralized ceilings and cross-ventilated
management of network, rooms.
communications, energy, security
and lighting.
ENERGY MODELING FINISH AND FIXTURE EXPERT VOLUNTEERS USAGE/BEHAVIOR
Climate-based siting, Solar >90% day-lit spaces, light Room level sub-metering
path finding, and continuous shelves, interior glazing, low and plug load
computed energy modeling maintenance finishes, ULF monitoring, open source
and air tightness testing plumbing fixtures, high Building Automation
throughout build process. efficiency hot water, Lifecycle Systems and sensors,
Building Center unprecedented simplified recycling and
incorporation of reclaimed composting.
building materials: furnishings,
finishes and fixtures.